| [{"name" |
-
•
"Material","values":["Oxygen free copper (99.97% purity)"]},{"name":"Diameter","values":["0.53 mm ± 0.02 mm (0.02" ± 0.0008")"]},{"name":"Wire Gauge","values":["24 AWG"]},{"name":"Material","values":["HDPE"]},{"name":"Min. Average Thickness","values":["0.21 mm (0.0083")"]},{"name":"Diameter","values":["0.95 mm ± 0.06 mm (0.04" ± 0.0024")"]},{"name":"Color","values":["8 cores, Blue, white/blue; Orange, white/orange; Green, white/green; Brown, white/brown"]},{"name":"Material","values":["Polyester"]},{"name":"Specification","values":["3 × 150D"]},{"name":"Material","values":["PE"]},{"name":"Specification","values":["Translucent 4.3 × 0.35 mm"]},{"name":"Material","values":["PVC"]},{"name":"Min. Average Thickness","values":["0.45 mm (0.02")"]},{"name":"Diameter","values":["5.6 mm ± 0.4 mm (0.22" ± 0.02")"]},{"name":"Color","values":["White"]},{"name":"Material","values":["MDPE"]},{"name":"Min. Average Thickness","values":["0.5 mm (0.02")"]},{"name":"Diameter","values":["6.8 mm ± 0.4 mm (0.27" ± 0.02")"]},{"name":"Color","values":["Black"]},{"name":"Max. DC Resistance of a Single Conductor","values":["9.5 Ω / 100 m (328.08 ft)"]},{"name":"Min. Insulation Resistance","values":["5000 MΩ·km"]},{"name":"Max. DC Resistance Unbalance","values":["2% (pair intra), 4% (pairs inter)"]},{"name":"Dielectric Strength","values":["No breakdown with 1kV DC for 1 min"]},{"name":"Characteristic Impedance","values":["100 Ω ± 15 Ω"]},{"name":"Near-end Crosstalk","values":["≥39.30 dB / 100 m @ 250 MHz"]},{"name":"Max. Attenuation","values":["34.8 dB / 100 m @ 250 MHz"]},{"name":"Return Loss","values":["≥17.3 dB / 100 m @ 250 MHz"]},{"name":"Tensile Strength","values":["Sheath ≥13.5 MPa, insulation ≥16 MPa"]},{"name":"Elongation at Break","values":["Sheath ≥150%, insulation ≥300%"]},{"name":"Installation Bending Radius","values":[">8 times of outer cable diameter"]},{"name":"Conductor Elongation at Break","values":["≥10%"]},{"name":"Shrinkage of Insulation","values":["≤5%"]},{"name":"Color Migration Resistance of Insulation","values":["No migration"]},{"name":"Sheath Tensile Strength and Elongation at Break after Aging","values":["≥12.5 MPa, ≥100%"]},{"name":"Low Temperature Bending Test","values":["No cracking after the test"]},{"name":"Heat Shock Test","values":["No cracking after the test"]},{"name":"Operation Temperature","values":["–20 °C to +60 °C (–4 °F to +140 °F)"]},{"name":"Installation Temperature","values":["0 °C to +50 °C (32 °F to 122 °F)"]},{"name":"Storage Temperature and Humidity","values":["–10 °C to +40 °C (14 °F to 104 °F), <60% (RH)"]},{"name":"Vertical Flame Test","values":["Comply with IEC 60332-1-2"]},{"name":"Cable Length","values":["305.0 m ± 2 m (1,000.66 ft ± 6.56 ft)"]},{"name":"Packaging Method","values":["305 m (1,000 ft) a carton, one carton with 2 inner cartons"]},{"name":"Packaging Dimensions","values":["433 mm × 433 mm × 230 mm (17.05" × 17.05" × 9.06") (L × W × H)"]},{"name":"Transport Package Dimensions","values":["495 mm × 457 mm × 466 mm (19.49" × 17.99" × 18.35") (L × W × H)"]},{"name":"Net Weight","values":["13.5 kg ± 0.6 kg (29.76 lb ± 1.32 lb)"]},{"name":"Gross Weight","values":["14.5 kg ± 0.6 kg (31.97 lb ± 1.32 lb)"]},{"name":"Executive Standards","values":["Q/DXJ 067-2024"]},{"name":"","values":["305 m /carton Outdoor U/UTP CAT6, power over Ethernet, compatible with one cable"]},{"name":"","values":["High-purity oxygen-free copper conductor material"]},{"name":"","values":["Customized PE outer sheath,certain degree of waterproof Environmentally friendly and all materials used are RoHS compliant"]},{"name":"","values":["10-year warranty"]}]
|